22 0981_22 0980_08062019_224254.mp4
0 ft. - General Observation - CONNECTION AT MH 9 O'CLOCK
45.6 ft. - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 6"
100 ft. - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"
135.9 ft. - Water Level, Sag in pipe, 10 %of cross sectional area, Start
139.2 ft. - Fracture Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES
165.3 ft. - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"
248.7 ft. - Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES
255.1 ft. - Fracture Spiral, from 11 to 04 o'clock, within 8 inches of joint: YES
261.5 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES
264 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: NO
| Distance | Code | Observation |
|---|---|---|
| 135.9 | MWLS | — |
| 280.8 | AMH | 22 0980 |
| 139.2 | FM | — |
| 255.1 | FS | — |
| 100 | TFC | — |
| 0 | AMH | 22 0981 |
| 152.3 | MWLS | — |
| 261.5 | FM | — |
| 264 | FM | — |
| 165.3 | TFC | — |
| 0 | MGO | CONNECTION AT MH 9 O'CLOCK |
| 248.7 | FM | — |
| 0 | MWM | — |
| 0 | MWL | — |
| 45.6 | TFC | — |