Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 21, 2019, 09:40 AM
  • 22 0323_22 0322 _08212019_024150.mp4

Date
08/21/2019
W/O
782128
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00795
PipeID
P16610
Time
2:40 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6808
Sewer Name
22 CAMERON RELIEF TRUNK
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
35
Purpose
Routine Assessment
Project
RFIR_WO_782128_TV22121_AUG2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
22 0323
Downstream MH
22 0322
Dir. of Survey
Downstream
Length Surveyed
347.9 ft.
Total Length
347.9 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 22 0323 to 22 0322
MH: 22 0323MH: 22 0322downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 22 03230 ft. MWL - Water Level, 10 %of cross sectional area2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - MAG COAT THROUGHOUT2.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start232.1 ft. LR - Alignment Right, 50 %, Start321.6 ft. LR - Alignment Right, 50 %, Finish347.9 ft. MSA - Survey Abandoned - CAMERA NOT PULLING CABLE347.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish347.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (4)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COAT THROUGHOUT

    2.1 ft. - General Observation - MAG COAT THROUGHOUT

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Alignment Right, 50 %, Start

    232.1 ft. - Alignment Right, 50 %, Start

Observations (12)

DistanceCodeObservation
347.9MSACAMERA NOT PULLING CABLE
0MWM
232.1LR
2.1SAP
0MGOCONNECTION AT MH 3 O'CLOCK
2.1MGOMAG COAT THROUGHOUT
347.9SAP
321.6LR
0AMH22 0323
2.1SSS
347.9SSS
0MWL

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-08-21T02:40:15-07:00
documentation
PRO PIPE
is_lateral_inspection
false