- Date
- 07/12/2019
- W/O
- 771875
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00709
- PipeID
- P14733
- Time
- 1:53 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K6709
- Sewer Name
- 18 SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
- City
- WHITTIER
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 31
- Purpose
- Routine Assessment
- Project
- RFIR_WO_771875_TV18102_JUN2019
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 30 in.
- Width
- 30 in.
- Upstream MH
- 18 0882
- Downstream MH
- 18 0881
- Dir. of Survey
- Downstream
- Length Surveyed
- 745.1 ft.
- Total Length
- 745.1 ft.
- Structural Index
- 2
- Structural Quick
- 3Y2\
- Structural Rating
- 688
- O&M Index
- 2
- O&M Quick
- 312i
- O&M Rating
- 427
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 1115
Pipe schematic from manhole 18 0882 to 18 0881 Observation photos (4)

10.4 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

10.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

83.4 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

315.1 ft. - Roots Tap Barrell, at 12 o'clock, 5 %, within 8 inches of joint: NO