- Date
- 08/22/2019
- W/O
- 782187
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00003
- PipeID
- P00397
- Time
- 2:33 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K6910
- Sewer Name
- 08 DAVIDSON CITY TRUNK, SECTS 1,2,&3
- City
- CARSON
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 15
- Purpose
- Routine Assessment
- Project
- RFIR_WO_782187_TV08001_AUG2019_1
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 08 0347
- Downstream MH
- 08 0347A
- Dir. of Survey
- Upstream
- Length Surveyed
- 43 ft.
- Total Length
- 43 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 2
- O&M Quick
- 2200
- O&M Rating
- 4
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 7
Pipe schematic from manhole 08 0347 to 08 0347A Observation photos (2)

5.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

21.3 ft. - Lining Failure Wrinkled, from 08 to 04 o'clock, within 8 inches of joint: YES, Start