Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 23, 2019, 08:17 AM
  • 03 0317_03 0316_10232019_013830.mp4

Date
10/23/2019
W/O
0792616
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00359
PipeID
P04891
Time
1:17 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1283
Sewer Name
03 ANAHEIM STREET TRUNK
City
ANAHEIM
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
24
Purpose
Routine Assessment
Project
20191017MDM_ANAHEIM_STREET_TRUNK
Material
NRCP
Shape
Circular
Height
30 in.
Upstream MH
03 0317
Downstream MH
03 0316
Dir. of Survey
Downstream
Length Surveyed
324.9 ft.
Total Length
324.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 03 0317 to 03 0316
MH: 03 0317MH: 03 0316downstream0 ft. MGO - General Observation - MH CONN 3:00 ACTIVE0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:40AM2 ft. MGO - General Observation - 30" NRCP-CIPP2 ft. MGO - General Observation - WHITE BUILDUP ON LINER144.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open154.5 ft. LFZ - Lining Failure Other, from 02 to 04 o'clock, within 8 inches of joint: NO - POSSIBLE OUTER SUFACE CORROSION171.3 ft. LFZ - Lining Failure Other, from 08 to 10 o'clock, within 8 inches of joint: NO - POSSIBLE OUTER SUFACE CORRISON318.5 ft. LFZ - Lining Failure Other, from 12 to 03 o'clock, within 8 inches of joint: NO - POSSIBLE OUTER SURFACE CORROSION324.4 ft. MGO - General Observation - MH CONN 3:00 OPEN324.9 ft. AMH - Downstream Manhole, Survey Ends - 2:10AM

Observation photos (5)

  • General Observation - 30" NRCP-CIPP

    2 ft. - General Observation - 30" NRCP-CIPP

  • General Observation - WHITE BUILDUP ON LINER

    2 ft. - General Observation - WHITE BUILDUP ON LINER

  • Lining Failure Other, from 02 to 04 o'clock, within 8 inches of joint: NO - POSSIBLE OUTER SUFACE CORROSION

    154.5 ft. - Lining Failure Other, from 02 to 04 o'clock, within 8 inches of joint: NO - POSSIBLE OUTER SUFACE CORROSION

  • Lining Failure Other, from 08 to 10 o'clock, within 8 inches of joint: NO - POSSIBLE OUTER SUFACE CORRISON

    171.3 ft. - Lining Failure Other, from 08 to 10 o'clock, within 8 inches of joint: NO - POSSIBLE OUTER SUFACE CORRISON

  • Lining Failure Other, from 12 to 03 o'clock, within 8 inches of joint: NO - POSSIBLE OUTER SURFACE CORROSION

    318.5 ft. - Lining Failure Other, from 12 to 03 o'clock, within 8 inches of joint: NO - POSSIBLE OUTER SURFACE CORROSION

Observations (12)

DistanceCodeObservation
2MGO30" NRCP-CIPP
318.5LFZPOSSIBLE OUTER SURFACE CORROSION
324.9AMH2:10AM
0MGOMH CONN 3:00 ACTIVE
144.7TBOpen
2MGOWHITE BUILDUP ON LINER
154.5LFZPOSSIBLE OUTER SUFACE CORROSION
324.4MGOMH CONN 3:00 OPEN
0MWL
0MWM
171.3LFZPOSSIBLE OUTER SUFACE CORRISON
0AMH1:40AM

Properties (7)

custom_field_three
POSSIBLE OUTER SURFACE CORROSION
custom_field_two
4
customer
LACSD
datetime
2019-10-23T01:17:45-07:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection
false
lining
CIPP