Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 17, 2019, 12:01 PM
  • 03 0334_03 0333_10172019_050425.mp4

Date
10/17/2019
W/O
0792616
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00359
PipeID
P04908
Time
5:01 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1278
Sewer Name
03 ANAHEIM STREET TRUNK
City
ANAHEIM
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
24
Purpose
Routine Assessment
Project
20191017MDM_ANAHEIM_STREET_TRUNK
Material
NRCP
Shape
Circular
Height
30 in.
Upstream MH
03 0334
Downstream MH
03 0333
Dir. of Survey
Downstream
Length Surveyed
326 ft.
Total Length
326 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3200
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 03 0334 to 03 0333
MH: 03 0334MH: 03 0333downstream0 ft. AMH - Upstream Manhole, Survey Begins - 5:05AM0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - MH CONN 3:00 ACTIVE2 ft. MGO - General Observation - 30" NRCP + CIPP20.6 ft. MGO - General Observation - WHITE BUILDUP ON PIPE217.3 ft. MGP - General Photograph217.3 ft. RML - Roots Medium Lateral, from 12 to 06 o'clock, 20 %, within 8 inches of joint: NO217.3 ft. TBD - Tap Break-In Defective, at 12 o'clock, -, , within 8 inches of joint: NO, 6" - Active-20% ROOTS326 ft. AMH - Downstream Manhole, Survey Ends - 5:25AM

Observation photos (5)

  • General Observation - 30" NRCP + CIPP

    2 ft. - General Observation - 30" NRCP + CIPP

  • General Observation - WHITE BUILDUP ON PIPE

    20.6 ft. - General Observation - WHITE BUILDUP ON PIPE

  • General Photograph

    217.3 ft. - General Photograph

  • Roots Medium Lateral, from 12 to 06 o'clock, 20 %, within 8 inches of joint: NO

    217.3 ft. - Roots Medium Lateral, from 12 to 06 o'clock, 20 %, within 8 inches of joint: NO

  • Tap Break-In Defective, at 12 o'clock, -,  , within 8 inches of joint: NO, 6" - Active-20% ROOTS

    217.3 ft. - Tap Break-In Defective, at 12 o'clock, -, , within 8 inches of joint: NO, 6" - Active-20% ROOTS

Observations (10)

DistanceCodeObservation
217.3MGP
217.3RML
2MGO30" NRCP + CIPP
0AMH5:05AM
326AMH5:25AM
20.6MGOWHITE BUILDUP ON PIPE
0MWM
0MWL
0MGOMH CONN 3:00 ACTIVE
217.3TBDActive-20% ROOTS

Properties (6)

custom_field_two
4
customer
LACSD
datetime
2019-10-17T05:01:03-07:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection
false
lining
CIPP