- Date
- 10/22/2019
- W/O
- 0792773
- Weather
- Dry
- Operator/Surveyor
- FRANKLIN
- Sewer ID
- Z00228
- PipeID
- P01753
- Time
- 10:10 AM
- Certificate
- U-415-06024039
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G8108
- Sewer Name
- 01 WRIGHT ROAD TRUNK
- City
- SOUTH GATE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 11
- Purpose
- Capital Improvement Program Assesment
- Project
- 20191018DF_JOINT_OUTFALL_G_UNIT_9_TRUNK
- Material
- RCP-CTL
- Shape
- Circular
- Height
- 33 in.
- Upstream MH
- G 0317
- Downstream MH
- G 0316
- Dir. of Survey
- Downstream
- Length Surveyed
- 57.3 ft.
- Total Length
- 57.3 ft.
- Structural Index
- 3
- Structural Quick
- 5132
- Structural Rating
- 13
- O&M Index
- 1
- O&M Quick
- 1200
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 15
Pipe schematic from manhole G 0317 to G 0316 Observation photos (6)

0 ft. - Upstream Manhole, Survey Begins - 11:43 AM

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

27.7 ft. - General Photograph

31.2 ft. - General Photograph