Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 18, 2019, 05:46 PM
  • 01 0922_01 0921_10182019_114108.mp4

Date
10/18/2019
W/O
0792773
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00228
PipeID
P01759
Time
10:46 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G8106
Sewer Name
01 WRIGHT ROAD TRUNK
City
SOUTH GATE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
11
Purpose
Capital Improvement Program Assesment
Project
20191018DF_JOINT_OUTFALL_G_UNIT_9_TRUNK
Material
RCP-CTL
Shape
Circular
Height
30 in.
Upstream MH
01 0922
Downstream MH
01 0921
Dir. of Survey
Downstream
Length Surveyed
146.9 ft.
Total Length
146.9 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 01 0922 to 01 0921
MH: 01 0922MH: 01 0921downstream0 ft. AMH - Upstream Manhole, Survey Begins - 11:20 AM0.1 ft. MWM - Water Mark, 25 %of cross sectional area0.1 ft. MWL - Water Level, 20 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 65% MAG2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start24.1 ft. MGP - General Photograph80.5 ft. MGP - General Photograph144.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish144.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish144.9 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 65% MAG146.9 ft. MGO - General Observation - ROACHES @ MH146.9 ft. AMH - Downstream Manhole, Survey Ends - 12:06 PM146.9 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN146.9 ft. MGO - General Observation - Peeling & Flaking Throughout The Reach

Observation photos (6)

  • Upstream Manhole, Survey Begins - 11:20 AM

    0 ft. - Upstream Manhole, Survey Begins - 11:20 AM

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 65% MAG

    2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 65% MAG

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    24.1 ft. - General Photograph

  • General Photograph

    80.5 ft. - General Photograph

Observations (15)

DistanceCodeObservation
2SSS
0AMH11:20 AM
0.1MWM
144.9CM
146.9MGOROACHES @ MH
2SZ65% MAG
144.9SSS
0.1MWL
146.9AMH12:06 PM
146.9MGOConn. @ Mh, 9 O' Clock. OPEN
80.5MGP
24.1MGP
146.9MGOPeeling & Flaking Throughout The Reach
144.9SZ65% MAG
2CM

Properties (6)

custom_field_two
3
customer
LACSD
datetime
2019-10-18T10:46:32-07:00
documentation
FRANKLIN, BRAR, RUVALCABA, IGNACIO
is_lateral_inspection
false
year_laid
19280228