- Date
- 10/15/2019
- W/O
- 079719
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00234
- PipeID
- P18010
- Time
- 5:21 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1274
- Sewer Name
- 02 ARTESIA EXTENSION TRUNK
- City
- BELLFLOWER
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 38
- Purpose
- Routine Assessment
- Project
- 20191015MDM_ARTESIA_EXTENSION_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 16 in.
- Upstream MH
- 02 0005
- Downstream MH
- 02 0132
- Dir. of Survey
- Downstream
- Length Surveyed
- 49.7 ft.
- Total Length
- 49.7 ft.
- Structural Index
- 3
- Structural Quick
- 5131
- Structural Rating
- 16
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 18
Pipe schematic from manhole 02 0005 to 02 0132 Observation photos (6)

1 ft. - General Observation - 16" VCP AIR LINE INSPECTION

23.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT FLAKING

28.1 ft. - General Observation - 16" VCP

43.5 ft. - Hole, from 01 to 04 o'clock, within 8 inches of joint: YES - MISSING RIM OF PIPE AREA STILL SEALED

49.7 ft. - Survey Abandoned - BROKEN PIPE IN LINE

49.7 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 06 o'clock, , within 8 inches of joint: YES - BROKEN OUTER PIPE RIM