Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 16, 2017, 08:15 AM
  • 04 0133_04 0132_10162017_025531.mp4

Date
10/16/2017
W/O
0635601
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00900
PipeID
P22241
Time
1:15 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0651
Sewer Name
04 3RD STREET CONNECTION TRUNK
City
BEVERLY HILLS
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 04
Page No.
03
Purpose
Routine Assessment
Project
20171016MDM_3RD_STREET_CONNECTION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
04 0133
Downstream MH
04 0132
Dir. of Survey
Downstream
Length Surveyed
3 ft.
Total Length
3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
5131
O&M Rating
8
Overall Index
4
Overall Quick
Overall Rating
8
Pipe schematic from manhole 04 0133 to 04 0132
MH: 04 0133MH: 04 0132downstream0 ft. MWL - Water Level, 80 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:50AM0 ft. MWM - Water Mark, 100 %of cross sectional area0 ft. DAGS - Deposits Attached Grease, 20 %of cross sectional area, at 02 o'clock, , within 8 inches of joint: NO3 ft. MSA - Survey Abandoned - DOWNLEG UPSTREAM SIPHON SOUTH

Observation photos (3)

  • Water Mark, 100 %of cross sectional area

    0 ft. - Water Mark, 100 %of cross sectional area

  • Deposits Attached Grease, 20 %of cross sectional area, at 02 o'clock,  , within 8 inches of joint: NO

    0 ft. - Deposits Attached Grease, 20 %of cross sectional area, at 02 o'clock, , within 8 inches of joint: NO

  • Survey Abandoned - DOWNLEG UPSTREAM SIPHON SOUTH

    3 ft. - Survey Abandoned - DOWNLEG UPSTREAM SIPHON SOUTH

Observations (5)

DistanceCodeObservation
0MWL
0AMH2:50AM
0MWM
3MSADOWNLEG UPSTREAM SIPHON SOUTH
0DAGS

Properties (7)

additional_info
DOWNLEG UPSTREAM SIPHON SOUTH
custom_field_two
4
customer
LACSD
datetime
2017-10-16T01:15:06-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false
lining
CIPP