Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 12, 2017, 07:24 PM
  • 29 0232_29 0063A_10122017_124615.mp4

Date
10/12/2017
W/O
0667689
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z01015
PipeID
P24135
Time
12:24 PM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7536
Sewer Name
29 EASTSIDE INTERCEPTOR SEWER
City
SIGNAL HILL
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
20171012SHO_EASTSIDE_INTERCEPTOR_SEWER
Material
CIP
Shape
Circular
Height
8 in.
Upstream MH
29 0232
Downstream MH
29 0063A
Dir. of Survey
Downstream
Length Surveyed
151.7 ft.
Total Length
151.7 ft.
Structural Index
2
Structural Quick
2200
Structural Rating
4
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 29 0232 to 29 0063A
MH: 29 0232MH: 29 0063Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 12450 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"72 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"73.5 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"96.7 ft. MMC - Material Change, Cast Iron105.9 ft. MMC - Material Change, Vitrified clay pipe139.1 ft. SSS - Surface Spalling, at 01 o'clock, within 8 inches of joint: YES151.7 ft. JOL - Joint Offset Large151.7 ft. AMH - Downstream Manhole, Survey Ends - 10 FEET SHY OF MH BUT WAS ABLE TO ZOOM INTO TO 63A151.7 ft. MMC - Material Change, Cast Iron

Observation photos (4)

  • Material Change, Cast Iron

    96.7 ft. - Material Change, Cast Iron

  • Joint Offset Large

    151.7 ft. - Joint Offset Large

  • Downstream Manhole, Survey Ends - 10 FEET SHY OF MH BUT WAS ABLE TO ZOOM INTO TO 63A

    151.7 ft. - Downstream Manhole, Survey Ends - 10 FEET SHY OF MH BUT WAS ABLE TO ZOOM INTO TO 63A

  • Material Change, Cast Iron

    151.7 ft. - Material Change, Cast Iron

Observations (12)

DistanceCodeObservation
151.7JOL
96.7MMC
105.9MMC
151.7AMH10 FEET SHY OF MH BUT WAS ABLE TO ZOOM INTO TO 63A
0AMH1245
73.5TFA
139.1SSS
72TFA
9TFA
0MWL
151.7MMC
0MWM

Properties (6)

custom_field_three
LARGE OFFSET JOINT & SPALLING
custom_field_two
3
customer
LACSD
datetime
2017-10-12T12:24:51-07:00
documentation
OBREGON, IGNACIO, FRANKLIN, BRAR
is_lateral_inspection
false