Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 6, 2017, 03:46 PM
  • 01 0119A_01 0119_962017_085217.mp4

Date
09/06/2017
W/O
0657949
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00203
PipeID
P01186
Time
8:46 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7506
Sewer Name
01 COMPTON CREEK EXTENSION TRUNK, SECTION 1
City
LOS ANGELES
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
12
Purpose
Maintenance Related
Project
20170906SHO_COMPTON_CREEK_EXTENSION_TRUNK_SECTION_1
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
01 0119
Downstream MH
01 0119A
Dir. of Survey
Upstream
Length Surveyed
233.4 ft.
Total Length
233.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 01 0119 to 01 0119A
MH: 01 0119MH: 01 0119Aupstream0 ft. MGO - General Observation - ACTIVE CONNECTION @ 3 IN THE MH0 ft. AMH - Upstream Manhole, Survey Ends - 09050.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish231.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start233.4 ft. AMH - Downstream Manhole, Survey Begins - 0855233.4 ft. MWL - Water Level, 20 %of cross sectional area233.4 ft. MGO - General Observation - CAPPED CONNECTION @ 3 IN THE MH233.4 ft. MWM - Water Mark, 35 %of cross sectional area

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
2DAGS
0AMH0855
233.4MGOACTIVE CONNECTION @ 3 IN THE MH
233.4AMH0905
233.3DAGS
0MWL
0MGOCAPPED CONNECTION @ 3 IN THE MH
0MWM

Properties (7)

additional_info
GREASE INSPECTION ONLY
custom_field_three
GREASE INSPECTION ONLY
custom_field_two
5
customer
LACSD
datetime
2017-09-06T08:46:51-07:00
documentation
OBREGON, IGNACIO, FRANKLIN, BRAR
is_lateral_inspection
false