Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 6, 2017, 12:33 PM
  • 01 1100_01 1099_262017_044657.mp4

Date
02/06/2017
W/O
0613635
Weather
Heavy Rain
Operator/Surveyor
MARTIN
Sewer ID
Z00210
PipeID
P01950
Time
4:33 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0431
Sewer Name
01 HUNTINGTON PARK TRUNK
City
HUNTINGTON PARK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
07
Purpose
Capital Improvement Program Assesment
Project
20170206MDM_HUNTINGTON_PARK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
01 1100
Downstream MH
01 1099
Dir. of Survey
Downstream
Length Surveyed
301.1 ft.
Total Length
301.1 ft.
Structural Index
2
Structural Quick
322B
Structural Rating
34
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
34
Pipe schematic from manhole 01 1100 to 01 1099
MH: 01 1100MH: 01 1099downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:45AM0 ft. MWM - Water Mark, 40 %of cross sectional area23.8 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Open43.9 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - HAIRLINE48.8 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SLIGHT50.2 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Open51.4 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - SL51.4 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SL86.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open101.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H119.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H124.6 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H125.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open132.1 ft. MGO - General Observation - 18" VCP155.6 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - H175.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open178.9 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H182.7 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: NO - SL201.7 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SL221 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H225.8 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H227.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open231 ft. FC - Fracture Circumferential, from 10 to 01 o'clock, within 8 inches of joint: YES - SLIGHT276.7 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Open282 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: NO - SL285.8 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H301.1 ft. AMH - Downstream Manhole, Survey Ends - 5:15AM

Observation photos (1)

  • General Observation - 18" VCP

    132.1 ft. - General Observation - 18" VCP

Observations (28)

DistanceCodeObservation
0MWL
178.9FCH
221FCH
51.4FCSL
51.4FCSL
201.7FCSL
48.8FCSLIGHT
125.5TFOpen
155.6FCH
86.6TFOpen
50.2TFOpen
231FCSLIGHT
285.8FCH
119.3FLH
132.1MGO18" VCP
182.7FCSL
227.1TFOpen
175.2TFOpen
0AMH4:45AM
43.9FCHAIRLINE
276.7TFOpen
301.1AMH5:15AM
101.2FLH
23.8TFOpen
225.8FCH
124.6FCH
0MWM
282FCSL

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2017-02-06T04:33:44-08:00
documentation
MARTIN,MANANES,REVELES
is_lateral_inspection
false