Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 29, 2015, 06:26 PM
  • 29 0531_29 0530_12292015_102856.mp4

Date
12/29/2015
W/O
PENDING
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z01106
PipeID
P24586
Time
10:26 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7028
Sewer Name
29 19TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Maintenance Related
Project
20151228AM_19TH_STREET_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0531
Downstream MH
29 0530
Dir. of Survey
Downstream
Length Surveyed
274.3 ft.
Total Length
274.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
3125
O&M Rating
13
Overall Index
2
Overall Quick
Overall Rating
13
Pipe schematic from manhole 29 0531 to 29 0530
MH: 29 0531MH: 29 0530downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 10:28 AM41.3 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN, 40% ROOTS91.7 ft. TFD - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE, 15% BLOCKED, CRACKED120.6 ft. TFD - Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 6" - OPEN, 15% ROOTS, BROKEN141.4 ft. TFD - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6" - OPEN, 90% ROOTS, BROKEN164.5 ft. RML - Roots Medium Lateral, from 08 to 10 o'clock, 10 %, within 8 inches of joint: YES165.2 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE, 100% ROOTS242.1 ft. TFD - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6" - OPEN, BROKEN274.2 ft. MGO - General Observation - BROKEN CONN. INSIDE THE MH. @ 09 O'CLOCK274.3 ft. AMH - Downstream Manhole, Survey Ends - 10:59 AM

Observation photos (8)

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN, 40% ROOTS

    41.3 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN, 40% ROOTS

  • Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE, 15% BLOCKED, CRACKED

    91.7 ft. - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE, 15% BLOCKED, CRACKED

  • Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 6" - OPEN, 15% ROOTS, BROKEN

    120.6 ft. - Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 6" - OPEN, 15% ROOTS, BROKEN

  • Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6" - OPEN, 90% ROOTS, BROKEN

    141.4 ft. - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6" - OPEN, 90% ROOTS, BROKEN

  • Roots Medium Lateral, from 08 to 10 o'clock, 10 %, within 8 inches of joint: YES

    164.5 ft. - Roots Medium Lateral, from 08 to 10 o'clock, 10 %, within 8 inches of joint: YES

  • Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE, 100% ROOTS

    165.2 ft. - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE, 100% ROOTS

  • Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6" - OPEN, BROKEN

    242.1 ft. - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6" - OPEN, BROKEN

  • General Observation - BROKEN CONN. INSIDE THE MH. @ 09 O'CLOCK

    274.2 ft. - General Observation - BROKEN CONN. INSIDE THE MH. @ 09 O'CLOCK

Observations (11)

DistanceCodeObservation
141.4TFDOPEN, 90% ROOTS, BROKEN
274.2MGOBROKEN CONN. INSIDE THE MH. @ 09 O'CLOCK
164.5RML
120.6TFDOPEN, 15% ROOTS, BROKEN
0MWL
274.3AMH10:59 AM
91.7TFDACTIVE, 15% BLOCKED, CRACKED
165.2TFACTIVE, 100% ROOTS
0AMH10:28 AM
41.3TFDOPEN, 40% ROOTS
242.1TFDOPEN, BROKEN

Properties (7)

additional_info
LOOKING FOR BLOCKAGES IN THE LATERAL CONNECTIONS ONLY
custom_field_three
LATERAL CONN. INSPECTION ONLY
custom_field_two
5
customer
LACSD
datetime
2015-12-29T10:26:27-08:00
documentation
MIRANDA, REVELES, MIRABAL, FRANKLIN
is_lateral_inspection
false