Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 28, 2015, 06:56 PM
  • 29 0531_29 0530_12282015_110038.mp4

Date
12/28/2015
W/O
PENDING
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z01106
PipeID
P24586
Time
10:56 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7026
Sewer Name
29 19TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Maintenance Related
Project
20151228AM_19TH_STREET_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0531
Downstream MH
29 0530
Dir. of Survey
Downstream
Length Surveyed
242.4 ft.
Total Length
242.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 29 0531 to 29 0530
MH: 29 0531MH: 29 0530downstream0 ft. AMH - Upstream Manhole, Survey Begins - 11:00 AM, EMERGENCY INSPECTION0 ft. MWL - Water Level, 5 %of cross sectional area74.3 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 6" - OPEN91.9 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: YES, 6"121.1 ft. TFD - Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 6" - OPEN, BROKEN, 15% ROOTS242.4 ft. MSA - Survey Abandoned - BROKEN PIPE

Observation photos (3)

  • Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 6" - OPEN

    74.3 ft. - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 6" - OPEN

  • Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: YES, 6"

    91.9 ft. - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 6" - OPEN, BROKEN, 15% ROOTS

    121.1 ft. - Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 6" - OPEN, BROKEN, 15% ROOTS

Observations (6)

DistanceCodeObservation
242.4MSABROKEN PIPE
121.1TFDOPEN, BROKEN, 15% ROOTS
91.9TFA
0AMH11:00 AM, EMERGENCY INSPECTION
74.3TFOPEN
0MWL

Properties (7)

additional_info
EMERGENCY INSPECTION, CHECKING THE LATERAL CONN. AT HOUSE ADDRESS 2022 DAWSON AVE.
custom_field_three
EMERGENCY INSPECTION
custom_field_two
5
customer
LACSD
datetime
2015-12-28T10:56:10-08:00
documentation
MIRANDA, MIRABAL, FRANKLIN
is_lateral_inspection
false