Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 6, 2019, 05:45 AM
  • 02 0243_02 0242 _08052019_230324.mp4

Date
08/05/2019
W/O
782708
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00251
PipeID
P02551
Time
10:45 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6733
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
DOWNEY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
28
Purpose
V
Project
RFIR_WO_782708_TV02382_AUG2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0243
Downstream MH
02 0242
Dir. of Survey
Downstream
Length Surveyed
385.5 ft.
Total Length
385.5 ft.
Structural Index
4
Structural Quick
4N00
Structural Rating
300
O&M Index
2
O&M Quick
412N
O&M Rating
156
Overall Index
3
Overall Quick
Overall Rating
456
Pipe schematic from manhole 02 0243 to 02 0242
MH: 02 0243MH: 02 0242downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 02430 ft. MWL - Water Level, 30 %of cross sectional area2.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start7.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start28.7 ft. MWL - Water Level, 40 %of cross sectional area51.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"156.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"244.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"357.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"384.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish384.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish385.5 ft. AMH - Downstream Manhole, Survey Ends - 02 0242

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
357.5TFC
385.5AMH02 0242
7.1FM
244.7TFC
0MWM
384.4FM
28.7MWL
156.9TFC
51.5TFC
2.5DAGS
0AMH02 0243
384.4DAGS
0MWL

Properties (6)

additional_info
SC378232
custom_field_two
3
customer
LACSD
datetime
2019-08-05T22:45:31-07:00
documentation
PROPIPE
is_lateral_inspection
false