Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 9, 2019, 07:43 AM
  • 16 0167_16 0166_08092019_010132.mp4

Date
08/09/2019
W/O
782224
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00648
PipeID
P13199
Time
12:43 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6073
Sewer Name
16 ARROYO SECO TRUNK, SECTION 5
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
17
Purpose
Routine Assessment
Project
RFIR_WO_782224_TV16081_AUG2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
16 in.
Width
16 in.
Upstream MH
16 0167
Downstream MH
16 0166
Dir. of Survey
Downstream
Length Surveyed
411.9 ft.
Total Length
411.9 ft.
Structural Index
4
Structural Quick
514N
Structural Rating
313
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
317
Pipe schematic from manhole 16 0167 to 16 0166
MH: 16 0167MH: 16 0166downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 16 01673.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start7.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start60 ft. MGO - General Observation - slim coat throughout156.1 ft. B - Broken, from 09 to 03 o'clock, within 8 inches of joint: YES205.1 ft. RPP - Repair Patch, from 07 to 10 o'clock, within 8 inches of joint: YES392 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish410 ft. MGO - General Observation - CONNECTION AT 3'0 IN MH411 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish411.9 ft. AMH - Downstream Manhole, Survey Ends - 16 0166

Observation photos (5)

  • Upstream Manhole, Survey Begins - 16 0167

    0 ft. - Upstream Manhole, Survey Begins - 16 0167

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    3.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 09 to 03 o'clock, within 8 inches of joint: YES

    156.1 ft. - Broken, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Repair Patch, from 07 to 10 o'clock, within 8 inches of joint: YES

    205.1 ft. - Repair Patch, from 07 to 10 o'clock, within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
0MWL
411DAGS
156.1B
0MWM
0AMH16 0167
3.1DAGS
205.1RPP
60MGOslim coat throughout
392FM
7.3FM
410MGOCONNECTION AT 3'0 IN MH
411.9AMH16 0166

Properties (6)

additional_info
SC378403
custom_field_two
3
customer
LACSD
datetime
2019-08-09T00:43:37-07:00
documentation
PRO PIPE
is_lateral_inspection
false