16 0163_16 0162_08092019_030757.mp4

0 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

0 ft. - Upstream Manhole, Survey Begins - 16 0162
36.8 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"

165 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start
189.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
248.2 ft. - Crack Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES
395.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 89.9 | TBA | — |
| 267.2 | TBA | — |
| 374.3 | TBA | — |
| 197.9 | TBA | — |
| 521 | DAGS | — |
| 189.8 | FM | — |
| 521 | DAE | — |
| 0 | MWL | — |
| 248.2 | CM | — |
| 327 | TBA | — |
| 444.8 | TBA | — |
| 0 | DAGS | — |
| 0 | MWM | — |
| 395.7 | CM | — |
| 36.8 | TBA | — |
| 0 | AMH | 16 0162 |
| 165 | DAE | — |
| 147 | TBA | — |
| 521.6 | AMH | 16 0162 |