32 1170_32 1169_08152019_230147.mp4

0 ft. - Upstream Manhole, Survey Begins - 32 1170
2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
208.8 ft. - Roots Fine Barrell, from 10 to 04 o'clock, within 8 inches of joint: YES
335.1 ft. - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
335.1 ft. - Material Change, Cast Iron

340 ft. - General Observation - MAG COAT THROUGHOUT
| Distance | Code | Observation |
|---|---|---|
| 2 | SAP | — |
| 208.8 | RFB | — |
| 407 | DSZ | — |
| 335.1 | SAP | — |
| 219.8 | DSZ | DEBRIS |
| 407 | SSS | — |
| 408.6 | AMH | 32 1169 |
| 0 | AMH | 32 1170 |
| 340 | MGO | MAG COAT THROUGHOUT |
| 2 | DAGS | — |
| 300 | MGO | CAST IRON TUBERCULATION |
| 209.7 | TBA | — |
| 0 | MWL | — |
| 407 | DAGS | — |
| 407 | SCP | — |
| 214.2 | TFC | — |
| 335.1 | SCP | — |
| 335.1 | MMC | — |
| 0 | MWM | — |
| 2 | SSS | — |