Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 22, 2019, 07:16 AM
  • H 0608_H 0607 _08222019_001644.mp4

Date
08/22/2019
W/O
782253
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00190
PipeID
P11029
Time
12:16 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6875
Sewer Name
H JOINT OUTFALL H - UNIT 8G
City
WEST COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
24
Purpose
Routine Assessment
Project
RFIR_WO_782253_TV15150_AUG2019
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Width
42 in.
Upstream MH
H 0607
Downstream MH
H 0608
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
4
Structural Quick
5131
Structural Rating
8
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
12
Pipe schematic from manhole H 0607 to H 0608
MH: H 0607MH: H 0608upstream0 ft. MSA - Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON.0 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES0 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES2 ft. MWL - Water Level, 50 %of cross sectional area2 ft. AMH - Downstream Manhole, Survey Begins - H 06072 ft. MWM - Water Mark, 60 %of cross sectional area

Observation photos (3)

  • Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON.

    2 ft. - Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON.

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (6)

DistanceCodeObservation
0MWL
0AMHH 0607
2MSAVIEW OF UPLEG OF D/S SIPHON.
2SRV
2SAP
0MWM

Properties (7)

additional_info
SC378347
custom_field_two
5
customer
LACSD
datetime
2019-08-22T00:16:13-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
27198