Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 7, 2017, 09:33 AM
  • 21 0339_21 0338 _09072017_024541.mp4

Date
09/07/2017
W/O
635405
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00783
PipeID
P15540
Time
2:33 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4959
Sewer Name
21 RAILROAD STREET TRUNK
City
CITY OF INDUSTRY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
34
Purpose
Routine Assessment
Project
WO_635405_TV21031_AUG2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
21 0339
Downstream MH
21 0338
Dir. of Survey
Downstream
Length Surveyed
131.3 ft.
Total Length
131.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
3
Pipe schematic from manhole 21 0339 to 21 0338
MH: 21 0339MH: 21 0338downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 21 03390.1 ft. MWM - Water Mark, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start7.1 ft. VC - Vermin Cockroach54.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"131.3 ft. AMH - Downstream Manhole, Survey Ends - 21 0338131.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWL
0AMH21 0339
54.6TFC
2DAGS
0.1MWM
131.3AMH21 0338
131.3DAGS
7.1VC

Properties (6)

additional_info
SC345650
custom_field_two
3
customer
LACSD
datetime
2017-09-07T02:33:06-07:00
documentation
PROPIPE
is_lateral_inspection
false