Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 17, 2016, 11:46 AM
  • 16 0511_16 0510 _11172016_035600.mp4

Date
11/17/2016
W/O
596918
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00659
PipeID
P13562
Time
3:46 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3881
Sewer Name
16 LAMANDA PARK TRUNK
City
SAN MARINO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
18
Purpose
Routine Assessment
Project
WO_596918_TV16026_NOV2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
16 0511
Downstream MH
16 0510
Dir. of Survey
Downstream
Length Surveyed
259.7 ft.
Total Length
259.7 ft.
Structural Index
5
Structural Quick
5100
Structural Rating
5
O&M Index
1
O&M Quick
2112
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
9
Pipe schematic from manhole 16 0511 to 16 0510
MH: 16 0511MH: 16 0510downstream0 ft. AMH - Upstream Manhole, Survey Begins - 16 05110 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start14.1 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"25.3 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"64.6 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"86.9 ft. RFJ - Roots Fine Joint, at 03 o'clock, within 8 inches of joint: YES87.7 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"114.5 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"114.7 ft. RFC - Roots Fine Connection, at 11 o'clock123.3 ft. MMC - Material Change, Cast Iron123.3 ft. SRC - Surface Reinforcement Corroded, from 07 to 05 o'clock, within 8 inches of joint: YES, Start220.6 ft. SRC - Surface Reinforcement Corroded, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish220.6 ft. MMC - Material Change, Vitrified clay pipe255.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish259.7 ft. AMH - Downstream Manhole, Survey Ends - 16 0510

Observation photos (8)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"

    14.1 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"

    25.3 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"

    64.6 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"

  • Roots Fine Joint, at 03 o'clock, within 8 inches of joint: YES

    86.9 ft. - Roots Fine Joint, at 03 o'clock, within 8 inches of joint: YES

  • Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"

    87.7 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"

    114.5 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"

  • Material Change, Cast Iron

    123.3 ft. - Material Change, Cast Iron

Observations (17)

DistanceCodeObservation
87.7TBA
220.6SRC
0AMH16 0511
86.9RFJ
114.7RFC
123.3MMC
123.3SRC
259.7AMH16 0510
64.6TBA
255.9DAGS
114.5TBA
0MWM
25.3TBA
14.1TBA
0MWL
2.8DAGS
220.6MMC

Properties (6)