Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 8, 2016, 05:17 PM
  • 30 0185_30 0184 _08122016_091842.mp4

Date
12/08/2016
W/O
597389
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00860
PipeID
P17886
Time
9:17 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3845
Sewer Name
30 EL PORTO TRUNK
City
MANHATTEN BEACH
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
01
Purpose
Routine Assessment
Project
WO_597389_TV30002_OCT2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
30 0185
Downstream MH
30 0184
Dir. of Survey
Downstream
Length Surveyed
306.1 ft.
Total Length
306.1 ft.
Structural Index
3
Structural Quick
3622
Structural Rating
22
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
22
Pipe schematic from manhole 30 0185 to 30 0184
MH: 30 0185MH: 30 0184downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 30 01850 ft. MWM - Water Mark, 20 %of cross sectional area4.1 ft. CM - Crack Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES82.1 ft. CM - Crack Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES94 ft. CM - Crack Multiple, from 08 to 05 o'clock, within 8 inches of joint: YES106 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES133.1 ft. FC - Fracture Circumferential, from 07 to 09 o'clock, within 8 inches of joint: YES184 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES256 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES306.1 ft. AMH - Downstream Manhole, Survey Ends - 30 0184

Observation photos (7)

  • Crack Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

    4.1 ft. - Crack Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES

    82.1 ft. - Crack Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 05 o'clock, within 8 inches of joint: YES

    94 ft. - Crack Multiple, from 08 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    106 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 07 to 09 o'clock, within 8 inches of joint: YES

    133.1 ft. - Fracture Circumferential, from 07 to 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    184 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    256 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
0MWL
4.1CM
133.1FC
0AMH30 0185
94CM
306.1AMH30 0184
256CL
106FL
184CM
82.1CM
0MWM

Properties (6)

additional_info
SC304595
custom_field_two
3
customer
LACSD
datetime
2016-12-08T09:17:40-08:00
documentation
PROPIPE
is_lateral_inspection
false