Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 5, 2016, 09:24 AM
  • 18 0115_18 0114 _05102016_023808.mp4

Date
10/05/2016
W/O
597011
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00698
PipeID
P13935
Time
2:24 AM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3730
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
WO_597011_TV18083_OCT2016
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0114
Downstream MH
18 0115
Dir. of Survey
Upstream
Length Surveyed
281.1 ft.
Total Length
281.2 ft.
Structural Index
3
Structural Quick
413J
Structural Rating
178
O&M Index
2
O&M Quick
2J00
O&M Rating
110
Overall Index
3
Overall Quick
Overall Rating
288
Pipe schematic from manhole 18 0114 to 18 0115
MH: 18 0114MH: 18 0115upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 01153.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish6.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish21.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES32 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"37.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"37.9 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES55.1 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES80.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"86.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"132.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"138.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"181.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"186.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"218.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES223.8 ft. FM - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES233.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"239.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"278.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start279.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start281.2 ft. AMH - Downstream Manhole, Survey Begins - 18 0114281.2 ft. MWL - Water Level, 10 %of cross sectional area281.2 ft. MWM - Water Mark, 15 %of cross sectional area

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    57.4 ft. - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    63.1 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    226.1 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES

    243.3 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    259.5 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
243.4TFA
259.5CL
57.4FM
63.1CL
100.1TFC
2.3DAGS
0AMH18 0114
281.2AMH18 0115
201TFA
243.3SAV
194.6TFA
249.2TFC
277.6DAGS
47.6TFA
0MWL
2SAV
142.9TFA
0MWM
275SAV
94.6TFA
148.9TF
226.1CL
41.9TFC

Properties (6)

additional_info
SC303717
custom_field_two
3
customer
LACSD
datetime
2016-10-05T02:24:00-07:00
documentation
PRO-PIPE
is_lateral_inspection
false