Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 5, 2016, 06:37 AM
  • 18 0987_18 0117 _04102016_234831.mp4

Date
10/04/2016
W/O
597011
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00698
PipeID
P13938
Time
11:37 PM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3730
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
WO_597011_TV18083_OCT2016
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0987
Downstream MH
18 0117
Dir. of Survey
Downstream
Length Surveyed
175.1 ft.
Total Length
175.2 ft.
Structural Index
3
Structural Quick
3J00
Structural Rating
165
O&M Index
2
O&M Quick
2F00
O&M Rating
68
Overall Index
3
Overall Quick
Overall Rating
233
Pipe schematic from manhole 18 0987 to 18 0117
MH: 18 0987MH: 18 0117downstream0 ft. MGO - General Observation - CONNECTION AT MH 9 ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 18 09870 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start32.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"37.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"83.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"89.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"135 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"140.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"162.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"163.9 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES167.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"170 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish172.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish175.2 ft. AMH - Downstream Manhole, Survey Ends - 18 0117

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    3.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    163.9 ft. - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

Observations (18)

DistanceCodeObservation
0MGOCONNECTION AT MH 9 ACTIVE
170SAV
89.2TFC
140.8TFC
167.8TFC
2SAV
83.5TF
0AMH18 0987
175.2AMH18 0117
135TF
3.8DAGS
0MWM
163.9CM
162.1TFC
37.8TFC
32.2TFC
172.4DAGS
0MWL

Properties (6)

additional_info
SC303717
custom_field_two
3
customer
LACSD
datetime
2016-10-04T23:37:00-07:00
documentation
PRO-PIPE
is_lateral_inspection
false