Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 6, 2016, 07:00 AM
  • 18 0102_18 0101 _06102016_002441.mp4

Date
10/06/2016
W/O
597011
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00698
PipeID
P13922
Time
12:00 AM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3731
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
WO_597011_TV18083_OCT2016
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0102
Downstream MH
18 0101
Dir. of Survey
Downstream
Length Surveyed
229.3 ft.
Total Length
229.3 ft.
Structural Index
3
Structural Quick
3H2H
Structural Rating
228
O&M Index
2
O&M Quick
2H11
O&M Rating
91
Overall Index
2
Overall Quick
Overall Rating
319
Pipe schematic from manhole 18 0102 to 18 0101
MH: 18 0102MH: 18 0101downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 01020 ft. MGO - General Observation - CONNECTION AT MH 3 ACTIVE0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 ACTIVE2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start58.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"61.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"99.5 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES109.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"112.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"162.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"164.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4", 4"212.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"215.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"225 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish225 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish225 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish229.3 ft. VC - Vermin Cockroach229.3 ft. MGO - General Observation - CONNECTION AT MH 9 ACTIVE229.3 ft. AMH - Downstream Manhole, Survey Ends - 18 0101229.3 ft. MGO - General Observation - CONNECTION AT MH 3 ACTIVE

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    99.5 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (24)

DistanceCodeObservation
229.3VC
2DAGS
164.9TFC
162.3TFC
61.4TFC
0AMH18 0102
0MGOCONNECTION AT MH 3 ACTIVE
2SSS
215.5TFC
0MWL
2SAV
229.3MGOCONNECTION AT MH 9 ACTIVE
109.9TFC
229.3AMH18 0101
112.8TFC
212.4TFC
225DAGS
229.3MGOCONNECTION AT MH 3 ACTIVE
58.2TFC
225SSS
0MWM
225SAV
99.5CM
0MGOCONNECTION AT MH 9 ACTIVE

Properties (6)

additional_info
SC303718
custom_field_two
2
customer
LACSD
datetime
2016-10-06T00:00:08-07:00
documentation
PRO-PIPE
is_lateral_inspection
false