Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 5, 2016, 07:47 AM
  • 18 0122_18 0121 _05102016_005604.mp4

Date
10/05/2016
W/O
597011
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00698
PipeID
P13943
Time
12:47 AM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3730
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
WO_597011_TV18083_OCT2016
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0121
Downstream MH
18 0122
Dir. of Survey
Upstream
Length Surveyed
167.6 ft.
Total Length
167.6 ft.
Structural Index
3
Structural Quick
3E00
Structural Rating
96
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
100
Pipe schematic from manhole 18 0121 to 18 0122
MH: 18 0121MH: 18 0122upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 01220 ft. MGO - General Observation - CONNECTION AT MH 9 ACTIVE2.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish3.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish63.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"69.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"125 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"130.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"165.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start165.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start167.6 ft. AMH - Downstream Manhole, Survey Begins - 18 0121167.6 ft. MWL - Water Level, 5 %of cross sectional area167.6 ft. MGO - General Observation - CONNECTION AT MH 3 ACTIVE167.6 ft. MWM - Water Mark, 10 %of cross sectional area

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
97.8TFC
167.6AMH18 0122
164.8DAGS
0AMH18 0121
164SAV
2SAV
42.6TFC
0MWL
0MGOCONNECTION AT MH 3 ACTIVE
103.8TFC
37.1TFC
2.3DAGS
0MWM
167.6MGOCONNECTION AT MH 9 ACTIVE

Properties (6)

additional_info
SC303717
custom_field_two
3
customer
LACSD
datetime
2016-10-05T00:47:38-07:00
documentation
PRO-PIPE
is_lateral_inspection
false