Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 16, 2016, 07:58 AM
  • 29 0533_29 0532 _11152016_235906.mp4

Date
11/15/2016
W/O
596855
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00630
PipeID
P24592
Time
11:58 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4013
Sewer Name
29 CERRITOS AVENUE SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
WO_596855_TV29018_OCT2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
29 0533
Downstream MH
29 0532
Dir. of Survey
Downstream
Length Surveyed
253.2 ft.
Total Length
253.2 ft.
Structural Index
3
Structural Quick
3F00
Structural Rating
105
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
105
Pipe schematic from manhole 29 0533 to 29 0532
MH: 29 0533MH: 29 0532downstream0 ft. AMH - Upstream Manhole, Survey Begins - 29 05330 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWM - Water Mark, 5 %of cross sectional area34.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"37.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"59.1 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES77.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start125.5 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"130.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"133.5 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"217.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"220.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"249.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish253.2 ft. MGO - General Observation - COCKROACHES IN MANHOLE253.2 ft. AMH - Downstream Manhole, Survey Ends - 29 0532

Observation photos (4)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    59.1 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    77.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    253.2 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (16)

DistanceCodeObservation
0AMH29 0533
253.2MGOCOCKROACHES IN MANHOLE
37.1TFC
59.1CM
130.7TFC
0MWL
0MGOCOCKROACHES IN MANHOLE
249.5CM
125.5TBA
220.2TFA
34.4TFC
253.2AMH29 0532
0MWM
77.8CM
217.5TFC
133.5TFC

Properties (6)

additional_info
SC306405
custom_field_two
3
customer
LACSD
datetime
2016-11-15T23:58:47-08:00
documentation
PRO PIPE
is_lateral_inspection
false