Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 7, 2018, 12:10 PM
  • 04 0068_04 0047 _07022018_042311.mp4

Date
02/07/2018
W/O
685064
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00415
PipeID
P11803
Time
4:10 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5433
Sewer Name
04 SHERMAN TRUNK
City
WEST HOLLYWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 04
Page No.
03
Purpose
Routine Assessment
Project
WO_685064_TV04009_FEB2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
04 0068
Downstream MH
04 0047
Dir. of Survey
Downstream
Length Surveyed
324.1 ft.
Total Length
324.2 ft.
Structural Index
3
Structural Quick
4232
Structural Rating
18
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
21
Pipe schematic from manhole 04 0068 to 04 0047
MH: 04 0068MH: 04 0047downstream0 ft. AMH - Upstream Manhole, Survey Begins - 04 00680 ft. MWL - Water Level, 5 %of cross sectional area0.1 ft. MWM - Water Mark, 10 %of cross sectional area0.1 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK3.4 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start21.1 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6", 6" - GASKET HANGING INSIDE THE LATERAL29 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"34.7 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish61.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"63.1 ft. RFJ - Roots Fine Joint, at 10 o'clock, within 8 inches of joint: YES85.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"100.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"125.3 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start131.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"131.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start131.5 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish138.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"179.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"194.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"205.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"218.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"258.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"318.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish324.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK324.2 ft. MGO - General Observation - CONNECTION AT MH 12 O'CLOCK324.2 ft. AMH - Downstream Manhole, Survey Ends - 04 0047

Observation photos (3)

  • Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    3.4 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    125.3 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    131.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (26)

DistanceCodeObservation
324.2MGOCONNECTION AT MH 9 O'CLOCK
34.7FM
179.2TF
61.2TF
318.7CM
131.5CM
3.4FM
131.3TB
21.1TFDGASKET HANGING INSIDE THE LATERAL
218.7TFC
29TB
85.7TFC
324.2MGOCONNECTION AT MH 12 O'CLOCK
0.1MWM
63.1RFJ
205.4TFC
125.3CL
0AMH04 0068
100.5TFC
258.5TF
0MWL
324.2AMH04 0047
131.5CL
194.9TB
138.9TFC
0.1MGOCONNECTION AT MH 9 O'CLOCK

Properties (6)

additional_info
SC347071
custom_field_two
3
customer
LACSD
datetime
2018-02-07T04:10:00-08:00
documentation
PROPIPE
is_lateral_inspection
false