Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 6, 2018, 07:01 AM
  • 01 0799_01 0798A_05022018_230536.mp4

Date
02/05/2018
W/O
684850
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00197
PipeID
P01502
Time
11:01 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5431
Sewer Name
01 BULLIS ROAD-TEMPLE STREET TRUNK
City
LYNWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
17
Purpose
Routine Assessment
Project
WO_684850_TV01264_FEB2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0799
Downstream MH
01 0798A
Dir. of Survey
Downstream
Length Surveyed
29.3 ft.
Total Length
29.3 ft.
Structural Index
4
Structural Quick
4500
Structural Rating
20
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
24
Pipe schematic from manhole 01 0799 to 01 0798A
MH: 01 0799MH: 01 0798Adownstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 01 07994.8 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start28.1 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish29.3 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK29.3 ft. AMH - Downstream Manhole, Survey Ends - 01 0798A

Observation photos (1)

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    4.8 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWL
0MWM
4.8FM
29.3MGOCONNECTION AT MH 9 O'CLOCK
0MGOCONNECTION AT MH 3 O'CLOCK
28.1FM
0AMH01 0799
29.3AMH01 0798A

Properties (6)

additional_info
SC347069
custom_field_two
2
customer
LACSD
datetime
2018-02-05T23:01:42-08:00
documentation
PROPIPE
is_lateral_inspection
false