Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 23, 2018, 08:39 AM
  • 02 0425_02 0433_2232018_012333.mp4

Date
02/23/2018
W/O
0691943
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00312
PipeID
P02748
Time
12:39 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
HO751
Sewer Name
02 70TH WAY EXTENSION TRUNK
City
PARAMOUNT
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
35
Purpose
Routine Assessment
Project
20180223MDM_70TH_WAY_EXTENSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
02 0433
Downstream MH
02 0425
Dir. of Survey
Upstream
Length Surveyed
326.3 ft.
Total Length
326.3 ft.
Structural Index
2
Structural Quick
4133
Structural Rating
41
O&M Index
2
O&M Quick
4229
O&M Rating
26
Overall Index
2
Overall Quick
Overall Rating
67
Pipe schematic from manhole 02 0433 to 02 0425
MH: 02 0433MH: 02 0425upstream0 ft. AMH - Upstream Manhole, Survey Ends - 2:30AM7.6 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SL7.6 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SL22.7 ft. DAE - Deposits Attached Encrustation, 1 %of cross sectional area, from 08 to 10 o'clock, , within 8 inches of joint: YES22.7 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H27.8 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SL28 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES39.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active39.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES51 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 11 o'clock, , within 8 inches of joint: YES66.6 ft. DAE - Deposits Attached Encrustation, 2 %of cross sectional area, from 01 to 04 o'clock, , within 8 inches of joint: YES66.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL84.1 ft. MGO - General Observation - WHEELS CHANGED RESTART (CLIP#2)84.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped84.1 ft. MGO - General Observation - 25% MINERIAL DESPOSITE STOPPED CAMERA84.1 ft. DAE - Deposits Attached Encrustation, 25 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES86.9 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - H86.9 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - H91.8 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SL121.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped125.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL134.8 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL134.8 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SL169.7 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active169.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES173 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H218.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H233.2 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SL233.2 ft. DAE - Deposits Attached Encrustation, 3 %of cross sectional area, from 02 to 04 o'clock, , within 8 inches of joint: YES233.2 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL236.3 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active243.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped243.9 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 12 o'clock, , within 8 inches of joint: YES263.9 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 12 o'clock, , within 8 inches of joint: YES266.2 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H286 ft. MWM - Water Mark, 20 %of cross sectional area306.3 ft. MWM - Water Mark, 50 %of cross sectional area316 ft. MGO - General Observation - 15" VCP316.1 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - MODERATE316.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE326.3 ft. AMH - Downstream Manhole, Survey Begins - 12:45AM326.3 ft. MWL - Water Level, 10 %of cross sectional area326.3 ft. MWM - Water Mark, 30 %of cross sectional area

Observation photos (6)

  • Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - MODERATE

    10.2 ft. - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - MODERATE

  • General Observation - 15" VCP

    10.3 ft. - General Observation - 15" VCP

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

    201.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

  • General Observation - 25% MINERIAL DESPOSITE STOPPED CAMERA

    242.2 ft. - General Observation - 25% MINERIAL DESPOSITE STOPPED CAMERA

  • Deposits Attached Encrustation, 25 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    242.2 ft. - Deposits Attached Encrustation, 25 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    298.3 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

Observations (43)

DistanceCodeObservation
156.6TBActive
234.5FCSL
239.4FCH
90TBActive
259.7DAE
286.9TFActive
303.6DAE
93.1FCSL
10.3MGO15" VCP
82.4TFCCapped
191.5FCSL
0AMH12:45AM
93.1DAE
275.3DAE
242.2MGOWHEELS CHANGED RESTART (CLIP#2)
318.7FCSL
191.5FCSL
40.3MWM
286.9DAGS
259.7FLSL
82.4DAE
318.7FCSL
153.3FCH
201.2FMSL
108FLH
242.2TFCCapped
298.5FCSL
204.8TFCCapped
242.2MGO25% MINERIAL DESPOSITE STOPPED CAMERA
10.2FCMODERATE
156.6DAGS
60.1FCH
242.2DAE
20MWM
93.1FCSL
239.4FCH
303.6FCH
0MWL
62.4DAE
0MWM
10.2FLHAIRLINE
298.3DAE
326.3AMH2:30AM

Properties (6)

custom_field_three
MODERATE CIRCUM -SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2018-02-23T00:39:30-08:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false