Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 9, 2017, 08:33 AM
  • 05 1305_05 1304 _09032017_003343.mpg

Date
03/09/2017
W/O
624345
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00452
PipeID
P06520
Time
12:33 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4374
Sewer Name
05 GRAMERCY PLACE TRUNK, SECTION 3
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
WO_624345_TV05034_MAR2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
05 1305
Downstream MH
05 1304
Dir. of Survey
Downstream
Length Surveyed
464.4 ft.
Total Length
464.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2Q00
O&M Rating
184
Overall Index
2
Overall Quick
Overall Rating
184
Pipe schematic from manhole 05 1305 to 05 1304
MH: 05 1305MH: 05 1304downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 13050 ft. MWM - Water Mark, 25 %of cross sectional area6.1 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start228.2 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"464.4 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish464.4 ft. AMH - Downstream Manhole, Survey Ends - 05 1304

Observation photos (1)

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES, Start

    6.1 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
6.1DAE
0MWL
228.2TFA
0AMH05 1305
464.4DAE
0MWM
464.4AMH05 1304

Properties (6)

additional_info
SC306883
custom_field_two
4
customer
LACSD
datetime
2017-03-09T00:33:15-08:00
documentation
PROPIPE
is_lateral_inspection
false