- Date
- 03/01/2017
- W/O
- 619125
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00210
- PipeID
- P01932
- Time
- 12:57 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- 4362
- Sewer Name
- 01 HUNTINGTON PARK TRUNK
- City
- CUDAHY
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 08
- Purpose
- V
- Project
- WO_619125_TV01246_FEB2017
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 24 in.
- Upstream MH
- 01 1082
- Downstream MH
- 01 1083
- Dir. of Survey
- Upstream
- Length Surveyed
- 249 ft.
- Total Length
- 249 ft.
- Structural Index
- 3
- Structural Quick
- 413I
- Structural Rating
- 150
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 150
Pipe schematic from manhole 01 1082 to 01 1083 Observation photos (3)

3.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

245.4 ft. - Fracture Multiple, from 08 to 01 o'clock, within 8 inches of joint: YES

249 ft. - Joint Offset Large