Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 16, 2017, 08:30 AM
  • B 0802_B 0801 _02162017_004301.mp4

Date
02/16/2017
W/O
618953
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00112
PipeID
P09269
Time
12:30 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4243
Sewer Name
B JOINT OUTFALL B - UNIT 8J
City
ARCADIA
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
12
Purpose
Routine Assessment
Project
WO_618953_TV15059_FEB2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
B 0801
Downstream MH
B 0802
Dir. of Survey
Upstream
Length Surveyed
38 ft.
Total Length
38 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
3127
O&M Rating
17
Overall Index
2
Overall Quick
Overall Rating
17
Pipe schematic from manhole B 0801 to B 0802
MH: B 0801MH: B 0802upstream0 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - DEBRIS0 ft. MSA - Survey Abandoned - DUE TO DEBRIS. NO REVERSAL. STOP LOG AT U/S MH.0 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Finish4 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"36 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start38 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 2 O'CLOCK38 ft. AMH - Downstream Manhole, Survey Begins - B 080138 ft. MWL - Water Level, 25 %of cross sectional area

Observation photos (2)

  • Deposits Attached Grease, 10 %of cross sectional area, from 02 to 10 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Settled Other,  20 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES - DEBRIS

    38 ft. - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - DEBRIS

Observations (8)

DistanceCodeObservation
0MGOACTIVE CONNECTION AT MH 2 O'CLOCK
38DSZDEBRIS
34TBA
38MSADUE TO DEBRIS. NO REVERSAL. STOP LOG AT U/S MH.
2DAGS
0AMHB 0801
38DAGS
0MWL

Properties (6)

additional_info
SC306746
custom_field_two
5
customer
LACSD
datetime
2017-02-16T00:30:22-08:00
documentation
PRO PIPE
is_lateral_inspection
false