Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 11, 2016, 08:46 AM
  • 02 1380_02 1379 _11102016_020900.mp4

Date
10/11/2016
W/O
597385
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00245
PipeID
P03900
Time
1:46 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3427
Sewer Name
02 DITMAN STREET BRANCH TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
07A
Purpose
Routine Assessment
Project
WO_597385_TV02045_OCT2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
02 1380
Downstream MH
02 1379
Dir. of Survey
Downstream
Length Surveyed
366.2 ft.
Total Length
366.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
1
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 1380 to 02 1379
MH: 02 1380MH: 02 1379downstream0 ft. VC - Vermin Cockroach0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 13800 ft. MGO - General Observation - CONNECTION AT MH 9 ACTIVE0 ft. MGO - General Observation - CONNECTION AT MH 3 ACTIVE83.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"120.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"176.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"181.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"189.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"245.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"263 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"364.6 ft. VC - Vermin Cockroach366.2 ft. AMH - Downstream Manhole, Survey Ends - 02 1379

Observations (15)

DistanceCodeObservation
0VC
189.4TF
245.8TF
263TF
364.6VC
176.1TF
366.2AMH02 1379
120.3TF
0MWL
0MWM
0AMH02 1380
83.2TF
0MGOCONNECTION AT MH 9 ACTIVE
181.7TF
0MGOCONNECTION AT MH 3 ACTIVE

Properties (8)

additional_info
SC303461
custom_field_two
4
customer
LACSD
datetime
2016-10-11T01:46:30-07:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
PVCP-Folded/Reformed
year_laid
38394