Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 13, 2016, 05:25 AM
  • 02 1374_02 1373 _12102016_224615.mp4

Date
10/12/2016
W/O
597385
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00245
PipeID
P03894
Time
10:25 PM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3428
Sewer Name
02 DITMAN STREET BRANCH TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
WO_597385_TV02045_OCT2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
02 1374
Downstream MH
02 1373
Dir. of Survey
Downstream
Length Surveyed
319 ft.
Total Length
319.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
1
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 1374 to 02 1373
MH: 02 1374MH: 02 1373downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. VC - Vermin Cockroach0 ft. AMH - Upstream Manhole, Survey Begins - 02 137440.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"85.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"106.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"142.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"153.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"158.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"207.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"266.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"319.1 ft. AMH - Downstream Manhole, Survey Ends - 02 1373319.1 ft. VC - Vermin Cockroach

Observations (14)

DistanceCodeObservation
142.9TF
0MWL
319.1AMH02 1373
319.1VC
106.7TF
85.9TF
0MWM
0VC
266.5TF
158.2TF
207.3TF
40.6TF
0AMH02 1374
153.4TFA

Properties (8)

additional_info
SC303463
custom_field_two
4
customer
LACSD
datetime
2016-10-12T22:25:53-07:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
PVCP-Folded/Reformed
year_laid
38394