Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 13, 2016, 08:01 AM
  • 02 1371_02 1370 _13102016_001714.mp4

Date
10/13/2016
W/O
597385
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00245
PipeID
P04627
Time
1:01 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3428
Sewer Name
02 DITMAN STREET BRANCH TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
WO_597385_TV02045_OCT2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
02 1371
Downstream MH
02 1370
Dir. of Survey
Downstream
Length Surveyed
336 ft.
Total Length
336 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
4112
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 02 1371 to 02 1370
MH: 02 1371MH: 02 1370downstream0 ft. VC - Vermin Cockroach0 ft. AMH - Upstream Manhole, Survey Begins - 02 13710 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area27.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"92.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"142.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"195.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"238.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"256.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"336 ft. VC - Vermin Cockroach336 ft. AMH - Downstream Manhole, Survey Ends - 02 1370

Observations (12)

DistanceCodeObservation
256.1TF
92.5TF
142.7TF
195.5TF
0VC
336VC
0AMH02 1371
238.9TF
336AMH02 1370
0MWM
27.9TF
0MWL

Properties (8)

additional_info
SC303463
custom_field_two
4
customer
LACSD
datetime
2016-10-13T01:01:00-07:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
PVCP-Folded/Reformed
year_laid
38394