Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 18, 2016, 07:45 AM
  • 05 1405_05 1404 _17112016_234534.mp4

Date
11/17/2016
W/O
597388
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00449
PipeID
P06625
Time
11:45 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3828
Sewer Name
05 GARDENA PUMP RELIEF TRUNK, SECTS 2&3
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
WO_597388_TV05030_OCT2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
05 1405
Downstream MH
05 1404
Dir. of Survey
Downstream
Length Surveyed
659 ft.
Total Length
659 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
5
Pipe schematic from manhole 05 1405 to 05 1404
MH: 05 1405MH: 05 1404downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 14050 ft. MWM - Water Mark, 25 %of cross sectional area538.9 ft. RFJ - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES651 ft. RFJ - Roots Fine Joint, at 10 o'clock, within 8 inches of joint: NO651 ft. CM - Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES659 ft. AMH - Downstream Manhole, Survey Ends - 05 1404

Observation photos (3)

  • Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES

    538.9 ft. - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, at 10 o'clock, within 8 inches of joint: NO

    651 ft. - Roots Fine Joint, at 10 o'clock, within 8 inches of joint: NO

  • Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

    651 ft. - Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
0MWL
0AMH05 1405
538.9RFJ
651RFJ
0MWM
659AMH05 1404
651CM

Properties (6)

additional_info
SC304577
custom_field_two
4
customer
LACSD
datetime
2016-11-17T23:45:13-08:00
documentation
PROPIPE
is_lateral_inspection
false