Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 17, 2016, 08:23 AM
  • 05 1417_05 1416 _17112016_002356.mp4

Date
11/17/2016
W/O
597388
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00449
PipeID
P06637
Time
12:23 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3827
Sewer Name
05 GARDENA PUMP RELIEF TRUNK, SECTS 2&3
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
WO_597388_TV05030_OCT2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
05 1417
Downstream MH
05 1416
Dir. of Survey
Downstream
Length Surveyed
388.9 ft.
Total Length
388.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 05 1417 to 05 1416
MH: 05 1417MH: 05 1416downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 14170 ft. MWM - Water Mark, 25 %of cross sectional area388.9 ft. AMH - Downstream Manhole, Survey Ends - 05 1416

Observations (4)

DistanceCodeObservation
388.9AMH05 1416
0MWL
0AMH05 1417
0MWM

Properties (6)

additional_info
SC304576
custom_field_two
4
customer
LACSD
datetime
2016-11-17T00:23:24-08:00
documentation
PROPIPE
is_lateral_inspection
false