Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 6, 2016, 07:53 AM
  • 05 0806_05 0805 _05122016_235413.mp4

Date
12/05/2016
W/O
597374
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00553
PipeID
P06037
Time
11:53 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3842
Sewer Name
05 MANCHESTER-VERMONT DIVERSION EXTENSION TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
08
Purpose
Routine Assessment
Project
WO_597374_TV05320_OCT2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 0805
Downstream MH
05 0806
Dir. of Survey
Upstream
Length Surveyed
150.3 ft.
Total Length
150.3 ft.
Structural Index
3
Structural Quick
3300
Structural Rating
9
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 05 0805 to 05 0806
MH: 05 0805MH: 05 0806upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 080621.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES90.8 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES102.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES150.3 ft. MWL - Water Level, 10 %of cross sectional area150.3 ft. AMH - Downstream Manhole, Survey Begins - 05 0805150.3 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    47.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    59.5 ft. - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    128.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
128.8CM
59.5FL
47.8CM
0MWL
0AMH05 0805
150.3AMH05 0806
0MWM

Properties (6)

additional_info
SC304592
custom_field_two
3
customer
LACSD
datetime
2016-12-05T23:53:09-08:00
documentation
PROPIPE
is_lateral_inspection
false