Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 4, 2018, 07:24 AM
  • 15 0409_15 0408 _04052018_004811.mp4

Date
05/04/2018
W/O
695786
Weather
Light Rain
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00607
PipeID
P12332
Time
12:24 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5585
Sewer Name
15 HILL DRIVE EXTENSION TRUNK
City
ROSEMEAD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
27
Purpose
Routine Assessment
Project
WO_695786_TV15033_APR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
15 0409
Downstream MH
15 0408
Dir. of Survey
Downstream
Length Surveyed
376.7 ft.
Total Length
376.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2N00
O&M Rating
150
Overall Index
2
Overall Quick
Overall Rating
150
Pipe schematic from manhole 15 0409 to 15 0408
MH: 15 0409MH: 15 0408downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 04090 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start43.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"95.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"137.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"235.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"336.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"376.7 ft. MGO - General Observation - COCKROACHES IN MANHOLE376.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish376.7 ft. MGO - General Observation - CONNECTION CAPPED 10 O' CLOCK376.7 ft. AMH - Downstream Manhole, Survey Ends - 15 0409

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
376.7MGOCOCKROACHES IN MANHOLE
376.7DAGS
2DAGS
336.2TFA
0MWL
137.8TFA
43.6TFA
0AMH15 0409
376.7MGOCONNECTION CAPPED 10 O' CLOCK
0MWM
95.1TFA
235.2TFA
376.7AMH15 0409

Properties (7)

additional_info
SC358549
custom_field_two
4
customer
LACSD
datetime
2018-05-04T00:24:33-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
39203