Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 27, 2018, 09:52 AM
  • 15 0929_15 0411 _27042018_025829.mp4

Date
04/27/2018
W/O
695786
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00607
PipeID
P12335
Time
2:52 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5578
Sewer Name
15 HILL DRIVE EXTENSION TRUNK
City
ROSEMEAD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
27
Purpose
Routine Assessment
Project
WO_695786_TV15033_APR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
15 0929
Downstream MH
15 0411
Dir. of Survey
Downstream
Length Surveyed
63.5 ft.
Total Length
63.5 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
2
O&M Quick
2A00
O&M Rating
24
Overall Index
2
Overall Quick
Overall Rating
29
Pipe schematic from manhole 15 0929 to 15 0411
MH: 15 0929MH: 15 0411downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 09290 ft. MWL - Water Level, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock, , within 8 inches of joint: YES6.3 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES6.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start43.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"58.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES61.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish63.5 ft. AMH - Downstream Manhole, Survey Ends - 15 0411

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock, , within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    6.3 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    6.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    58.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

Observations (9)

DistanceCodeObservation
43.9TFA
6.3CM
63.5AMH15 0411
0AMH15 0929
61.9DAGS
58.2CL
2DAGS
6.3DAGS
0MWL

Properties (6)

additional_info
SC358539
custom_field_two
4
customer
LACSD
datetime
2018-04-27T02:52:31-07:00
documentation
PRO PIPE
is_lateral_inspection
false