Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 27, 2018, 07:41 AM
  • 15 0416_15 0415 _27042018_005047.mp4

Date
04/27/2018
W/O
695786
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00607
PipeID
P12341
Time
12:41 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5578
Sewer Name
15 HILL DRIVE EXTENSION TRUNK
City
ROSEMEAD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
27
Purpose
Routine Assessment
Project
WO_695786_TV15033_APR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0416
Downstream MH
15 0415
Dir. of Survey
Downstream
Length Surveyed
3.5 ft.
Total Length
3.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3121
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 15 0416 to 15 0415
MH: 15 0416MH: 15 0415downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 04162 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES3.5 ft. MSA - Survey Abandoned - DUE TO DEBRIS/DEPOSITS3.5 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES - DEBRIS

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES

  • Survey Abandoned - DUE TO DEBRIS/DEPOSITS

    3.5 ft. - Survey Abandoned - DUE TO DEBRIS/DEPOSITS

Observations (6)

DistanceCodeObservation
0MWM
0MWL
3.5MSADUE TO DEBRIS/DEPOSITS
3.5DSZDEBRIS
2DAGS
0AMH15 0416

Properties (6)

additional_info
SC358538
custom_field_two
5
customer
LACSD
datetime
2018-04-27T00:41:17-07:00
documentation
PRO PIPE
is_lateral_inspection
false