Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 26, 2018, 08:14 AM
  • 15 0873_15 0872 _26042018_012643.mp4

Date
04/26/2018
W/O
695662
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00599
PipeID
P12666
Time
1:14 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5577
Sewer Name
15 CALIFORNIA AVENUE TRUNK
City
MONROVIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
05
Purpose
Routine Assessment
Project
WO_695662_TV15182_APR2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
15 0872
Downstream MH
15 0873
Dir. of Survey
Upstream
Length Surveyed
263.2 ft.
Total Length
263.2 ft.
Structural Index
3
Structural Quick
3I00
Structural Rating
153
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
153
Pipe schematic from manhole 15 0872 to 15 0873
MH: 15 0872MH: 15 0873upstream0 ft. AMH - Upstream Manhole, Survey Ends - 15 08730 ft. MGO - General Observation - COCKROACHES IN MANHOLE1.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish21.5 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"96.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"257.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start257.6 ft. MGO - General Observation - MAG COATING THROUGHOUT 40%263.2 ft. MWL - Water Level, 15 %of cross sectional area263.2 ft. MWM - Water Mark, 25 %of cross sectional area263.2 ft. AMH - Downstream Manhole, Survey Begins - 15 0872

Observation photos (1)

  • General Observation - MAG COATING THROUGHOUT 40%

    5.6 ft. - General Observation - MAG COATING THROUGHOUT 40%

Observations (10)

DistanceCodeObservation
0MWL
0MWM
166.8TFA
5.6SAV
263.2AMH15 0873
0AMH15 0872
263.2MGOCOCKROACHES IN MANHOLE
5.6MGOMAG COATING THROUGHOUT 40%
262SAV
241.7TBA

Properties (6)

additional_info
SC358537
custom_field_two
2
customer
LACSD
datetime
2018-04-26T01:14:41-07:00
documentation
PRO PIPE
is_lateral_inspection
false