Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 10, 2019, 09:05 AM
  • 02 1166_02 1165_04102019_021741.mp4

Date
04/10/2019
W/O
761209
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00351
PipeID
P02950
Time
2:05 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5924
Sewer Name
02 GARFIELD AVENUE EXTENSION TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_761209_TV02318_APR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
02 1165
Downstream MH
02 1166
Dir. of Survey
Upstream
Length Surveyed
224.9 ft.
Total Length
224.9 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
2
O&M Quick
2H00
O&M Rating
90
Overall Index
2
Overall Quick
Overall Rating
94
Pipe schematic from manhole 02 1165 to 02 1166
MH: 02 1165MH: 02 1166upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 11660.7 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0.7 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish2.5 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish128.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"157.5 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start176.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"223.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start224.9 ft. AMH - Downstream Manhole, Survey Begins - 02 1165224.9 ft. MWM - Water Mark, 40 %of cross sectional area224.9 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (3)

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    67.4 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - CONNECTION AT MH 9 O'CLOCK

    224.2 ft. - General Observation - CONNECTION AT MH 9 O'CLOCK

  • General Observation - CONNECTION AT MH 3 O'CLOCK

    224.2 ft. - General Observation - CONNECTION AT MH 3 O'CLOCK

Observations (12)

DistanceCodeObservation
0AMH02 1165
48.5TFC
224.2MGOCONNECTION AT MH 9 O'CLOCK
1DAGS
222.4FM
96.4TFC
67.4FM
0MWM
224DAGS
224.2MGOCONNECTION AT MH 3 O'CLOCK
224.9AMH02 1166
0MWL

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-04-10T02:05:03-07:00
documentation
PROPIPE
is_lateral_inspection
false