Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 5, 2019, 08:39 AM
  • 02 1138_02 1137_04052019_015501.mp4

Date
04/05/2019
W/O
761209
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00351
PipeID
P02921
Time
1:39 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6514
Sewer Name
02 GARFIELD AVENUE EXTENSION TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_761209_TV02318_APR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1138
Downstream MH
02 1137
Dir. of Survey
Downstream
Length Surveyed
294.4 ft.
Total Length
294.4 ft.
Structural Index
5
Structural Quick
5341
Structural Rating
19
O&M Index
2
O&M Quick
412K
O&M Rating
123
Overall Index
2
Overall Quick
Overall Rating
142
Pipe schematic from manhole 02 1138 to 02 1137
MH: 02 1138MH: 02 1137downstream0 ft. MGO - General Observation - SERVICE CONNECTION AT 3 O' CLOCK AT MH0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 11381 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start1.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start5.3 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start15.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"63.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"115 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"162.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"214.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"216.1 ft. B - Broken, from 08 to 03 o'clock, within 8 inches of joint: YES244.2 ft. B - Fracture, from 07 to 12 o'clock, within 8 inches of joint: YES281.5 ft. B - Fracture, from 08 to 04 o'clock, within 8 inches of joint: YES293.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish293.2 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Finish294 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Finish294.4 ft. AMH - Downstream Manhole, Survey Ends - 02 1137

Observation photos (5)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    1.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start

    5.3 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start

  • Broken, from 08 to 03 o'clock, within 8 inches of joint: YES

    216.1 ft. - Broken, from 08 to 03 o'clock, within 8 inches of joint: YES

  • Fracture, from 07 to 12 o'clock, within 8 inches of joint: YES

    244.2 ft. - Fracture, from 07 to 12 o'clock, within 8 inches of joint: YES

  • Fracture, from 08 to 04 o'clock, within 8 inches of joint: YES

    281.5 ft. - Fracture, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
15.2TFC
216.1B
115TFC
63.1TFC
162.9TFC
1DAGS
0MGOSERVICE CONNECTION AT 3 O' CLOCK AT MH
0MWM
0MWL
293.2FM
1.6FM
214.5TFC
293.2RFJ
294.4AMH02 1137
244.2B
281.5B
0AMH02 1138
5.3RFJ
294DAGS

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-04-05T01:39:15-07:00
documentation
PROPIPE
is_lateral_inspection
false