Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 9, 2019, 05:10 AM
  • 02 1127_02 1126_04082019_223512.mp4

Date
04/08/2019
W/O
761209
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00351
PipeID
P02907
Time
10:10 PM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6516
Sewer Name
02 GARFIELD AVENUE EXTENSION TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_761209_TV02318_APR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1127
Downstream MH
02 1126
Dir. of Survey
Downstream
Length Surveyed
268.8 ft.
Total Length
268.8 ft.
Structural Index
3
Structural Quick
423J
Structural Rating
169
O&M Index
2
O&M Quick
412J
O&M Rating
112
Overall Index
3
Overall Quick
Overall Rating
281
Pipe schematic from manhole 02 1127 to 02 1126
MH: 02 1127MH: 02 1126downstream0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 11271 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start5.5 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES5.5 ft. CH2 - Crack Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"8.3 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start13.1 ft. FS - Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES16.8 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start55.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"102.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"153.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"209.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"218 ft. RFJ - Roots Fine Joint, from 02 to 04 o'clock, within 8 inches of joint: YES256.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"262.6 ft. RFJ - Roots Fine Joint, at 03 o'clock, within 8 inches of joint: YES265.7 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish268 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish268 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish268.8 ft. AMH - Downstream Manhole, Survey Ends - 02 1126

Observation photos (6)

  • Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES

    5.5 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES

    5.5 ft. - Crack Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    8.3 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES

    13.1 ft. - Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    16.8 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, at 03 o'clock, within 8 inches of joint: YES

    262.6 ft. - Roots Fine Joint, at 03 o'clock, within 8 inches of joint: YES

Observations (21)

DistanceCodeObservation
0MWL
5.5SSS
268DAGS
265.7FM
0MWM
268.8AMH02 1126
153.8TFC
1DAGS
209.3TFC
8.3CM
218RFJ
7TFC
262.6RFJ
268CM
0AMH02 1127
13.1FS
5.5CH2
55.2TFC
256.7TFC
102.3TFC
16.8FM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-04-08T22:10:47-07:00
documentation
PROPIPE
is_lateral_inspection
false