Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 4, 2019, 10:16 AM
  • 02 1153_02 1152_04042019_033006.mp4

Date
04/04/2019
W/O
761209
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00351
PipeID
P02937
Time
3:16 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6512
Sewer Name
02 GARFIELD AVENUE EXTENSION TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_761209_TV02318_APR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
02 1152
Downstream MH
02 1153
Dir. of Survey
Upstream
Length Surveyed
263.7 ft.
Total Length
263.7 ft.
Structural Index
4
Structural Quick
4R21
Structural Rating
386
O&M Index
2
O&M Quick
2J1A
O&M Rating
117
Overall Index
3
Overall Quick
Overall Rating
503
Pipe schematic from manhole 02 1152 to 02 1153
MH: 02 1152MH: 02 1153upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 11530 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish0.7 ft. FM - Crack Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES, Finish1.7 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish2.6 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Finish14.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"53.2 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start59.9 ft. RFJ - Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YESR63.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"112.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"165 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"213.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"230.7 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start236.8 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES249.3 ft. FM - Crack Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES, Start262.7 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start263.7 ft. AMH - Downstream Manhole, Survey Begins - 02 1152263.7 ft. MWM - Water Mark, 35 %of cross sectional area263.7 ft. MGO - General Observation - SERVICE CONNECTION AT 9 O'CLOCK AT MH263.7 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (5)

  • Crack Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES, Start

    14.4 ft. - Crack Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    26.9 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    33 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YESR

    203.8 ft. - Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YESR

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start

    210.5 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start

Observations (20)

DistanceCodeObservation
0AMH02 1152
0MWM
210.5RFJ
249.2TFC
0MGOSERVICE CONNECTION AT 9 O'CLOCK AT MH
151TFC
98.7TFC
203.8RFJ
261.1RFJ
49.9TFC
262FM
33FM
263.7AMH02 1153
0MWL
200.5TFC
26.9CL
263.7DAGS
14.4FM
1DAGS
263FM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-04-04T03:16:37-07:00
documentation
PROPIPE
is_lateral_inspection
false