Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 4, 2019, 08:13 AM
  • 02 1154_02 1153_04042019_012847.mp4

Date
04/04/2019
W/O
761209
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00351
PipeID
P02938
Time
1:13 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6512
Sewer Name
02 GARFIELD AVENUE EXTENSION TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_761209_TV02318_APR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
02 1154
Downstream MH
02 1153
Dir. of Survey
Downstream
Length Surveyed
222.8 ft.
Total Length
222.8 ft.
Structural Index
4
Structural Quick
4131
Structural Rating
7
O&M Index
2
O&M Quick
2H15
O&M Rating
95
Overall Index
2
Overall Quick
Overall Rating
102
Pipe schematic from manhole 02 1154 to 02 1153
MH: 02 1154MH: 02 1153downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 11540 ft. MGO - General Observation - SERVICE CONNECTION AT 9 O'CLOCK AT MH0.1 ft. MGO - General Observation - CHANNEL BROKEN0.1 ft. MGO - General Observation - SERVICE CONNECTION AT 3 O' CLOCK AT MH1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start3.5 ft. CM - Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES12.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start15.7 ft. RFJ - Roots Fine Joint, at 03 o'clock, within 8 inches of joint: YESR79 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"116.7 ft. RFJ - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR130.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"172.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES177.6 ft. RFJ - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR182.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"192.7 ft. RFJ - Roots Fine Joint, at 11 o'clock, within 8 inches of joint: YESR214.1 ft. RFJ - Roots Fine Joint, at 10 o'clock, within 8 inches of joint: YESR219.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish222.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish222.8 ft. AMH - Downstream Manhole, Survey Ends - 02 1153

Observation photos (8)

  • Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

    3.5 ft. - Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    12.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, at 03 o'clock, within 8 inches of joint: YESR

    15.7 ft. - Roots Fine Joint, at 03 o'clock, within 8 inches of joint: YESR

  • Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR

    116.7 ft. - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR

  • Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    172.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR

    177.6 ft. - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR

  • Roots Fine Joint, at 11 o'clock, within 8 inches of joint: YESR

    192.7 ft. - Roots Fine Joint, at 11 o'clock, within 8 inches of joint: YESR

  • Roots Fine Joint, at 10 o'clock, within 8 inches of joint: YESR

    214.1 ft. - Roots Fine Joint, at 10 o'clock, within 8 inches of joint: YESR

Observations (21)

DistanceCodeObservation
182.7TFC
79TFC
219.8FM
0MWM
192.7RFJ
3.5CM
116.7RFJ
130.2TFC
222.8AMH02 1153
15.7RFJ
0MWL
1DAGS
172.6DAGS
0AMH02 1154
177.6RFJ
214.1RFJ
0MGOSERVICE CONNECTION AT 9 O'CLOCK AT MH
0.1MGOCHANNEL BROKEN
222.6DAGS
0.1MGOSERVICE CONNECTION AT 3 O' CLOCK AT MH
12.6FM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-04-04T01:13:56-07:00
documentation
PROPIPE
is_lateral_inspection
false