Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 4, 2019, 09:16 AM
  • 02 1150_02 1149_04042019_022945.mp4

Date
04/04/2019
W/O
761209
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00351
PipeID
P02934
Time
2:16 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6512
Sewer Name
02 GARFIELD AVENUE EXTENSION TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_761209_TV02318_APR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1150
Downstream MH
02 1149
Dir. of Survey
Downstream
Length Surveyed
343 ft.
Total Length
343 ft.
Structural Index
4
Structural Quick
4L00
Structural Rating
264
O&M Index
3
O&M Quick
3M11
O&M Rating
205
Overall Index
3
Overall Quick
Overall Rating
469
Pipe schematic from manhole 02 1150 to 02 1149
MH: 02 1150MH: 02 1149downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - SERVICE CONNECTION AT 3 O' CLOCK AT MH0 ft. AMH - Upstream Manhole, Survey Begins - 02 11500 ft. MWM - Water Mark, 35 %of cross sectional area1.1 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start6.9 ft. TBB - Tap Break-In Abandoned, at 10 o'clock, -, within 8 inches of joint: YES, 6"9.5 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start19.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"67.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"152.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"212.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"255.9 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6"258.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"315.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"316.4 ft. RFJ - Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YESR339.7 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish343 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish343 ft. AMH - Downstream Manhole, Survey Ends - 02 1149

Observation photos (3)

  • Tap Break-In Abandoned, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    6.9 ft. - Tap Break-In Abandoned, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    9.5 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YESR

    316.4 ft. - Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YESR

Observations (18)

DistanceCodeObservation
0MWL
316.4RFJ
212.3TFC
1.1DAGS
255.9TB
258.9TF
343DAGS
9.5FM
19.3TFC
339.7FM
152.5TF
0MGOSERVICE CONNECTION AT 3 O' CLOCK AT MH
0AMH02 1150
6.9TBB
343AMH02 1149
67.6TFC
0MWM
315.4TFC

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-04-04T02:16:46-07:00
documentation
PROPIPE
is_lateral_inspection
false